SINUS PENTA
PROGRAMMING GUIDE
126/486
P099 Fire Mode Speed
P099
Range
32000 ÷ 32000
±32000 rpm
Default
750
750.00 rpm
Level
ENGINEERING
Address
699
Function
Determines the value of the output speed in Fire Mode. The Fire Mode speed
depends on the unit of measure programmed in P100.
P100 Multispeed Unit of Measure
P100
Range
0 ÷ 2
0: [0.01 rpm] ÷ 2: [1.0 rpm]
Default
2
2: [1.0 rpm]
Level
ADVANCED
Address
700
Function
Determines the unit of measure considered for the 15 allowable multispeed values
and the Fire Mode speed in P099.
CAUTION
When changing the unit of measure of the multispeed values in P100
, the preset speed
values for the multispeed and Fire Mode values will be RECOMPUTED.