PROGRAMMING GUIDE
SINUS PENTA
417/486
C316 Clock/Calendar Editing Command
C316
Range
0 ÷ 1
0 ÷ 1
Default
0
0
Level
ADVANCED
Active
This parameter can be viewed and changed only if the Data Logger ES851
is installed and activated (R021 = ENABLE).
Address
1244
Function
If this parameter is set to 1, all the values set in parameters C310 to C315
are written and stored to the clock/calendar
of the board and the measures
described above are instantly changed.
CAUTION
Also unchanged parameters are written to
the clock/calendar. Make sure that
unchanged parameters are correct.