7 CARE AND MAINTENANCE
7.32 MHL360 E
Item
Diesel engine exhaust system
O = Check, carry out maintenance
x = Replace
every 500 h
every 2000 h
every 4500 h
every 6000 h
Per year
2 years
22
Visual inspection
O
O
23
Exhaust gas recirculation, adjusting rod play
O
24
Filter element of the diesel particle filter on the ash lamp display (only by
service personnel authorized by the engine manufacturer)
25 Spark plug of the burner on the diesel particle filter (only by service person-
nel authorized by the engine manufacturer)
X
Item
Hydraulic system
O = Check, carry out maintenance
x = Replace
every 500 h
every 1000 h
every 3000 h
every 6000 h
Per year
2 years
26 Check pump drive and attachment
O
O
27
Clean the cooling fins of the hydraulic oil cooler.
h If there is a heavy accumulation of dust, shorten the cleaning intervals.
O O
28 Vent the oscillating axle cylinder
O
O
29
Change or check hydraulic oil
2), 3)
O
X
X
30
Replace hydraulic oil tank ventilation filter
1)
X
X
31
Replace return filter insert
X
X
32
Replace the filter element in the slewing circuit and grab (optional)
X
X
1 A filter element must always be changed if the clogging indicator responds at the operating temperature of the hy-
draulic system and the signal stays on continuously.
2 Extension of hydraulic oil change intervals
Hydraulic oil change based on oil sample analyses and lab report. Oil sample intervals as specified by test lab.
3 Shortening of the hydraulic oil change intervals
If the loading machine is generally operated with a hydraulic hammer or under difficult conditions (frequent chang-
ing of work attachment, surroundings exposed to dust), there is a danger the hydraulic oil will become more con-
taminated than normal.
To prevent the hydraulic components wearing prematurely as a result, the oil change intervals (and/or the intervals
between oil samples) should be reduced.