CARE AND MAINTENANCE 7
MHL360 E 7.43
7.7.3.6 Draining water from the fuel sys-
tem
h Carry out maintenance as described in
chapter 7.6.4 Maintenance and inspection
plan.
Water must be drained daily from the fuel
system through the fuel tank and the fuel pre-
filter.
ATTENTION
Collect the fuel/water mixture in a
suitable reservoir. Do not allow
them to seep into the ground or wa-
ter! Give to an authorized waste
disposal company to dispose of in
an environmentally-friendly manner.
Fuel tank
Remove the fuel drain plug (285/1) from
the fuel tank and replace it with the drain
valve from the tool box included in the
scope of supply.
Screw the drain hose onto the drain valve
and drain the condensate. Once fuel in-
stead of water starts to flow, close the
drain valve.
ATTENTION
Keep the level of fuel in the tank high to prevent
condensation from building up.
Fuel prefilter
If the message (286/25) "Water in fuel"
appears on the display, open the drain
valve (283/2) on the fuel prefilter. Collect
the water/fuel mixture that drains out in a
suitable container. Close the drain valve
(283/2) when only fuel flows out. Dispose
of the collected water/fuel mixture properly.
BSB50025
1
Fig. 285 Fuel drain plug
F
09 :43 11 .03. 2 011
MH LX X X / XXX X
18 00 U PM
0 5 1 0 15 20 2 5
95°C 7 C
0 ½ 1
9 %
120 0
BSB50608
25
34
Fig. 286 Water in fuel