CDM-625 Advanced Satellite Modem Revision 13
Appendix D MN-CDM625
D–58
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to
Query
BUC
Temperature
N/A
4 bytes
Query only.
BUCTemperature, in the form sxxx, where:
s = sign
xxx = number
Note: This query is only valid when the FSK and BUC power are turned On.
N/A
BUT?
Exception
600L Emulation:
ODT?
BUT=sxxx
(see Description of
Arguments)
BUC
Phase Lock
Loop
N/A
1 byte, value
of 0 or 1
Query only.
BUC phase lock loop in the form x, where:
0 = Locked
1 = Unlocked
Note: This query is only valid when the FSK is enabled.
N/A
BPA?
Exception
600L Emulation:
OLL?
BPA=x
(see Description of
Arguments)
BUC Software
Version
N/A
2 bytes
Query only.
BUC software version in the form xx, where xx is between 0 and 15.
Note: This query is only valid when the FSK and BUC power are turned On.
N/A
BSV?
Exception
600L Emulation:
OSV?
BSV=xx
(see Description of
Arguments)
BUC
Power Class
N/A
2 bytes
Query only.
BUC Power Class in the form xx, where xx indicates the Power Class in watts.
Example: BPC=25
Note: This query is only valid when the FSK is enabled.
N/A
BPC?
Exception
600L Emulation:
OPC?
BPC=xx
(see Description of
Arguments)