NOTE: The terminal attaching clip(s) must face out-
board. Failure to reorient the terminal(s) may result
in an additional failure.
(4) Properly orient the new terminal(s) wit h t he
attachin g clip fa cing out board in the or iginal loca-
tion(s) on the grid bus bar and hold the ter minal(s)
with a m etal pick or other suitable pointed t ool.
CAUTION: Do not allow the glass surface to exceed
204° C (400° F), glass may fracture.
NOTE: New rear window defogger terminals are pre-
soldered and fluxed. Do not reuse a terminal if it
has been previously heated.
Pla ce th e solder gun on to the n ew terminal(s) a nd
heat th e term ina l unt il th e solder flows. Remove the
solder gu n and contin ue to hold the ter mina l in the
correct posit ion for an addit iona l five seconds.
(5) Allow the solder to cool for ten minut es.
NOTE: To ensure proper installation, do not attach
the wire harness connector(s) to the terminal(s)
until the solder is completely cooled.
(6) After the solder has cooled, reconnect t he wire
harness connector(s) a nd ver ify oper ation of the rear
window defogger.
8G - 8 H EAT ED GL AS S VA