MASTER LOCK SWITCH
SWITCH POSITION CONTINUITY BETWEEN
OPEN 4 AND 7
4 AND 10
7 AND 10
LOCK/UNLOCK 3 AND 4
3 AND 7
3 AND 10
4 AND 7
4 AND 10
4 AND 8
7 AND 8
7 AND 10
REMOVAL
(1) Disconn ect and isolate the battery nega tive
cable.
(2) Remove the instrument panel cent er bezel
(Refer to 23 - BODY/INSTRUMENT PANEL/IN-
STRUME NT PANE L CENTER BE ZEL -
REMOVAL).
(3) Remove the cen tral locking swit ch from the
bezel (Fig. 2).
INSTALLATION
(1) In st all switch to bezel.
(2) In st all instrument pa nel center bezel (Refer to
23 - BODY/INSTRUMENT PANE L/INSTRUMENT
PANEL CENTER BE ZEL - INSTALLATION).
(3) Connect batt ery n egat ive cable.
Fig. 1 POWER LOCK SWITCH Fig. 2 POWER LOCK SWITCH
1 - CENTRAL LOCKING SWITCH
2 - INSTRUMENT PANEL
8N - 2 P OW ER L OCKS VA