2-40 MFP Service Manual
7500-432, -632, and -832
202.01 Sensor (fuser exit) off (too short) jam
Step Check Yes No
1 Check the media position.
Open the printer left door assembly, and visually check it.
Does the media touch the sensor (fuser exit)?
Remove the
media.
Go to step 2.
2 Check the fuser unit assembly for a media jam.
Open the printer left door assembly, and check it.
Is there a media jam in the fuser unit assembly?
Remove the
media.
Go to step 3.
3 Check the fuser unit assembly for proper installation.
Open the printer left door assembly, and check it.
Is the fuser unit assembly installed properly?
Go to step 4. Install the fuser
unit assembly
properly.
Go to “Fuser unit
assembly
removal” on
page 4-104.
4 Check the roll.
Open the printer left door assembly, and check it.
Is the transport roll assembly free of excess wear and
contamination?
Go to step 5. Clean or replace
the transport roll
assembly.
Go to “Transfer
roll guide
assembly
removal” on
page 4-77.
5 Check the sensor (fuser exit) for operation.
1. Enter the Diagnostics Menu.
2. Touch BASE SENSOR TEST.
3. Touch Media Path.
4. Touch Fuser exit.
Open the printer left door assembly, and check it.
The area around the actuator is very hot. Allow the
fuser area to cool before proceeding.
Does the display on the operator panel change every time
the sensor actuator is operated?
Go to step 7. Go to step 6.
6 Check the sensor (fuser exit) connection.
Is the sensor (fuser exit) properly connected?
Replace the
sensor (fuser exit).
Go to “Sensor
(fuser exit)
removal” on
page 4-103.
Replace the
connection.
7 Perform a print test.
Does the error continue?
Replace the
printer engine card
assembly.
Go to “Printer
engine card
assembly
removal” on
page 4-119.
Problem solved.