Diagnostic information 2-113
7500-432, -632, and -832
294.01 Sensor (ADF pre-registration) on jam side 2
Step Check Yes No
1 Check the original document condition.
Is the original document free of paper clips and staples as
well as damage such as creases, tears, holes, or excessive
wear?
Go to step 2. Remove damaged
original document
and replace with a
new undamaged
original document.
Perform a ADF
test. If the problem
remains, go to
step 2.
2 Check the ADF rolls for wear.
Is the ADF feed/pick roll assembly or the ADF separation
roll guide assembly free of excess wear?
Go to step 3. Clean or replace
the ADF feed/pick
roll assembly or
the ADF
separation roll
guide assembly.
Go to “ADF feed/
pick roll
assembly
removal” on
page 4-186 or
“ADF separation
roll guide
assembly” on
page 4-203.
3 Check the media path for contaminates.
Is the media path free of excess media dust and foreign
objects such as paper clips and staples?
Go to step 4. Remove all
contaminates from
the media path.
4 Check the inverter gate condition.
Is the inverter gate free of damage and warpage; and does
it move smoothly?
Go to step 5. Replace the
inverter gate.
Go to “Inverter
gate removal” on
page 4-199.
5 Check the sensor (ADF pre registration) for operation.
Perform the sensor (ADF pre registration) test.
Open the ADF left cover assembly.
1. Enter the Diagnostics Menu.
2. Touch SCANNER TESTS.
3. Touch Sensor Tests.
4. Touch ADF pre registration.
Operate the actuator of the sensor (ADF pre registration).
Does the display on the operator panel change every time
the sensing area of the above sensor is blocked?
Go to step 7. Go to step 6.
6 Check the sensor (ADF pre-registration) for connection.
Is the above sensor connected properly?
Replace the
sensor (ADF pre-
registration).
Go to “Sensor
(ADF pre-
registration)” on
page 4-196.
Replace the
connection.