Diagnostic aids 3-13
7500-432, -632, and -832
Sensor Test (output bin)
This test is used to verify that a specific output bin’s sensors are working correctly.
To run the Output Bin Sensor Test:
1. Touch OUTPUT BIN TESTS from the Diagnostics Menu.
2. Touch Sensor Test.
The panel displays each installed bin, one bin per line. When you select an output bin, the panel displays the
selected output bin in the header row, and then displays the name of each of the bin’s sensors. You must select
a specific sensor from this list in order to view and toggle the sensor’s state. After selecting a specific sensor,
[Sensor Name] Testing... the sensor’s name in the header row appears on the display and, below the header
row, the sensor’s name and current state. The table below indicates which sensors are available in each output
bin.
When you select a specific sensor, the sensor’s current state (Open or Closed) appears on the display. You can
manipulate the printer in such a way as to actuate the selected sensor. Closed appears on the display when the
sensor is closed, or Open when the sensor is open. If the wrong message is displayed, then the sensor must be
malfunctioning.
Press Stop to exit the test.
FINISHER TESTS
Staple Test
This test is used to verify the functioning of the finisher’s staple mechanism.
To run the Staple Test
1. Touch FINISHER TESTS from the Diagnostics Menu.
2. Touch Staple Test.
The printer feeds eight pieces of media from the default input source to the output bin that supports stapling.
After all eight pieces of media are deposited, the device staples the packet. While this test runs, Staple Test
Running... appears on the display.
Press Stop to cancel the test.
Output Bin
Std bin full
exit1
Std bin full
exit2
Fin upper bin
full
Stacker bin
level1
Stacker bin
level2
Standard Bin
Output Bin 1
Output Bin 2