Loading...
3-12 MFP Service Manual
7500-432, -632, and -832
Go Back
Previous
Next
After selecting a specific sensor, you can manipulate the printer in such a way as to toggle the sensor between
its two values (Open or Closed).
Press Stop to exit the test.
OUTPUT BIN TESTS
Feed Tests (output bins)
Use these tests to verify that media can be fed to a specific output bin. Media is fed from the default input source
to the selected output bin. No information is printed on the media fed to the output bin because the printhead is
not engaged during this test. These tests can use any media size or envelope supported by the printer.
To run the Feed Tests for the output bins:
1. Touch OUTPUT BIN TESTS from the Diagnostics Menu.
2. Touch Feed Tests.
3. Touch the output bin you want the paper to exit into. The standard bin as well as any output option bin
installed on the printer is shown on the menu. (The output bins are displayed in the order installed on the
printer.)
Standard Bin
Output Bin 1
Output Bin 2
4. Touch either Single or Continuous.
Single—Feeds one sheet of media from the selected source.
Continuous—Media continues feeding from the selected source until Stop is pressed.
Press Stop to return to OUTPUT BIN TESTS.
While this test runs, [Selected Output Bin] Feeding...appears on the display. During Single tests, no buttons
are active. However, during Continuous tests, you can press Stop to cancel the test. If a test is canceled,
[Selected Output Bin] Canceled appears on the display.
Feed To All Bins
This test can be used to verify that the printer can feed media to the standard bin or any installed output options.
No information will be printed on the test pages, as the printhead is not engaged during the feed test. The media
feeds from the default paper source.
To run the Feed To All Bins Test:
1. Touch OUTPUT BIN TESTS from the Diagnostics Menu.
2. Touch Feed To All Bins.
The printer feeds media from the default source to each installed bin. After the test is selected, the printer feeds
a separate piece of media to the standard bin first, then it feeds a separate piece of media to each output bin
installed. While this test runs, All Bin Test Feeding... appears on the display.
The test is continuous until Stop is pressed. If a test is canceled, All Bin Test Canceled... appears on the
display, and feeds any remaining media in the paper path to the appropriate output destination.

Table of Contents