EasyManua.ls Logo

Lexmark X862de - CCD Initialization (Lamp Off) Failure; Scanner Communication Failure

Lexmark X862de
851 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-140 MFP Service Manual
7500-432, -632, and -832
Go Back
Previous
Next
845.02 CCD initialization (lamp off) failure
846.00 Scanner communication failure
5 Perform a POR.
Does the error remain when the power is turned off/on?
Replace the
scanner
controller card
assembly.
Go to “Scanner
controller card
assembly
removal” on
page 4-151.
Problem solved.
Step Check Yes No
1 Check the connection of the scanner controller card
assembly.
Are the connectors of the scanner controller card assembly
connected properly?
Go to step 2. Connect each
connector of the
scanner
controller card
assembly
properly.
2 Perform a POR.
Does the error remain when the power is turned off/on?
Replace the
scanner
controller card
assembly.
Go to “Scanner
controller card
assembly
removal” on
page 4-151.
Problem solved.
3 Perform a POR.
Does the error remain when the power is turned off/on again?
Replace the
scanner PS card
assembly.
Go to “Scanner
PS card
assembly
removal” on
page 4-162.
Problem solved.
Step Check Yes No
1 Check the scanner interface cable assembly connection
between the RIP card assembly and the scanner unit
assembly.
Is the scanner interface cable assembly connected properly?
Go to step 2. Replace the
connection.
2 Check all connections of the scanner controller card assembly.
Are the connections of the scanner controller card assembly
connected properly?
Go to step 3. Connect each
connector of the
scanner
controller card
assembly
properly.
Step Check Yes No

Table of Contents