ADF feed-out roll assembly removal
1. Remove the ADF unit assembly. See “ADF unit assembly removal” on page 4-167.
2. Open the ADF left cover assembly.
3. Remove the ADF front cover assembly. See ADF front cover assembly removal” on page 4-174.
4. Remove the ADF rear cover. See “ADF rear cover removal” on page 4-173.
5. Remove the document tray assembly. See Document tray assembly removal” on page 4-172.
6. Remove the ADF registration motor. See “ADF registration motor removal” on page 4-209.
7. Remove the ADF media feed assembly. See “ADF media feed assembly removal” on page 4-170.
8. Remove the ADF feed drive motor assembly. See “ADF feed drive motor assembly removal” on
page 4-180.
9. Lift the separation roll guide assembly to its uppermost position.
10. Remove the actuator/media guide assembly. See “Actuator/media guide assembly removal” on
page 4-198.
11. Loosen the screw securing the tension bracket (A) and loosen the registration secondary belt (B) tension.
12. Remove the tension spring (B).
13. Loosen the screw securing the small tension bracket (C).
14. Remove the exit roll drive belt (D).
15. Remove the registration secondary drive belt (E).
16. Remove the plastic clip securing the exit/feed-out roll drive pulley 25/28T (F).
17. Remove the exit/feed-out roll drive pulley 25/28T (F).
18. Remove the bearing 8 mm (G) securing the ADF feed-out roll assembly (H) to the rear of the feed
assembly.
19. Remove the plastic clip securing the manual feed drive pulley (I).
20. Remove the manual feed drive pulley (I).
21. Remove the manual feed drive belt (J).
22. Remove the bearing 8 mm (K) securing the feed-out roll assembly to the front of the feed assembly.