4-156 MFP Service Manual
7500-432, -632, and -832
Sensor (platen length APS 1) removal
1. Remove the large platen glass. See “Large platen glass removal” on page 4-150.
2. Remove the eight screws securing the cover (A) to the scanner unit assembly.
3. Remove the cover (A).
4. Disconnect the sensor (platen length APS 1) (B).
5. Remove the screw securing the sensor (platen length APS 1) (B).
6. Remove the sensor (platen length APS 1) (B).
Note: Ensure that the blue connector is plugged into the sensor (platen length APS 1) (B).