EasyManua.ls Logo

Lexmark X862de - Scanner Drive Motor Assembly Removal

Lexmark X862de
851 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Repair information 4-163
7500-432, -632, and -832
Go Back
Previous
Next
Scanner drive motor assembly removal
1. Remove the ADF unit assembly. See “ADF unit assembly removal” on page 4-167.
2. Remove the scanner left cover. See “Scanner left cover removal” on page 4-133.
3. Remove the scanner right cover. See “Scanner right cover removal” on page 4-134.
4. Remove the scanner top rear cover. See “Scanner top rear cover removal” on page 4-132.
5. Disconnect the connector from the scanner drive motor assembly (A).
6. Remove the scanner drive motor tension spring (B) from the scanner drive motor assembly (A).
7. Remove the three screws securing the scanner drive motor assembly (A) to the scanner unit assembly.
8. Remove the scanner drive motor assembly (A).
Note: To correctly set the scanner drive belt (C) tension, install the scanner drive motor assembly (A) and
the scanner drive motor tension spring (B) before completely tightening the three screws.
A
C
B
Connector

Table of Contents

Related product manuals