EasyManua.ls Logo

Lexmark X862de - Hole Punch Test

Lexmark X862de
851 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-14 MFP Service Manual
7500-432, -632, and -832
Go Back
Previous
Next
Hole Punch Test
This test is used to verify that media can be fed to a finisher output bin and then hole punched. No information is
printed on the feed test pages.
To run the Hole Punch Test:
1. Touch FINISHER TESTS from the Diagnostics Menu.
2. Touch Hole Punch Test.
Eight sheets of paper are fed, and then the pages are hole-punched with a 2-hole or 3-hole pattern depending
on the selected punch test. Media is initially requested from the default input source and then output to the
Finisher output bin.
The Hole Punch Test cannot be canceled. No buttons are active during this test. During the test, Hole Punch
Test Running... appears on the display. After completion of the test, the display returns to the Hole Punch Test
screen.
Feed Tests (Finisher)
This test is used to verify that media can be fed to a finisher output bin. This test feeds one sheet of media from
the printer’s default input source to a finisher output bin. The device can perform this test using any paper size
that is supported by the finisher. No information is printed on the test page.
To run the Feed Test:
1. Touch FINISHER TESTS from the Diagnostics Menu.
2. Touch Feed Tests.
You cannot specify the output bin to which the device will feed the test page. Once begun, the Feed Test cannot
be canceled. No buttons are active during the test. During this test, Feed Test Running... appears on the
display.
Sensor Test (Finisher)
This test verifies that the sensors in the finisher are operating properly.
To run the Feed Test:
1. Touch FINISHER TESTS from the Diagnostics Menu.
2. Touch Sensor Test.
The option’s name in the header row and each of the option’s sensors below the header row appear on the
display. You must select a specific sensor from this list in order to view and toggle the sensor’s state. After
selecting a specific sensor, [Sensor Name] Testing... appears on the display with the sensor’s current state
below this message. The tables below indicate which sensors are available for testing.
Available Cover and Door Sensors
Sensor Name Description
Cover F bridge top Sensor (bridge unit top cover interlock)
Door G finisher front Switch (finisher front door interlock)
Surface H finisher eject Switch (eject cover interlock)