2-112 MFP Service Manual
7500-432, -632, and -832
294.00 Sensor (ADF inverter) static jam
Step Check Yes No
1 Check the sensor (ADF inverter).
Is the feed media path free of media or media fragments?
Go to step 2. Remove any
media or media
fragments.
2 Check the sensor (ADF inverter) for operation.
Perform the sensor (ADF inverter) test.
Open the ADF left cover assembly.
Remove the ADF separation roll guide assembly. Go to “ADF
separation roll guide assembly” on page 4-203.
1. Enter the Diagnostics Menu.
2. Touch SCANNER TESTS.
3. Touch Sensor Tests.
4. Touch ADF inverter.
Insert a sheet of paper into the ADF paper path entrance.
Manually rotate the ADF exit roll assembly by hand to feed the
sheet through the ADF to operate the actuator of the sensor
(ADF inverter).
Does the display on the operator panel change every time the
sensing area of the above sensor is blocked?
Go to step 4. Go to step 3.
3 Check the sensor (ADF inverter) for connection.
Is the above sensor connected properly?
Replace the
sensor (ADF
inverter).
Go to “Sensor
(ADF inverter)”
on page 4-197.
Replace the
connection.
4 Place an undamaged document in the ADF, and perform a
ADF test.
Does the error remain?
Replace the
ADF controller
card assembly.
Go to “ADF
controller card
assembly
removal” on
page 4-175.
Go to step 5.
5 Place an undamaged document in the ADF, and perform a
ADF test.
Does the error remain?
Replace the
RIP card
assembly.
Go to “RIP
card assembly
removal” on
page 4-130.
Problem solved.