Diagnostic information 2-101
7500-432, -632, and -832
9 Check the feed drive motor for connection.
Is the above sensor connected properly?
Replace the
ADF feed drive
motor
assembly.
Go to “ADF
feed drive
motor
assembly
removal” on
page 4-180.
Replace the
connection.
10 Check the inverter solenoid assembly for operation.
Perform the inverter solenoid test.
Open the ADF left cover assembly.
Remove the ADF front cover assembly. Go to “ADF front
cover assembly removal” on page 4-174.
Close the ADF left cover assembly.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch Scanner Motor Tests.
4. Touch Inverter solenoid.
Does the inverter solenoid assembly operate properly?
Go to step 12. Go to step 11.
11 Check the inverter solenoid assembly for connection.
Is the above motor connected properly?
Replace the
inverter
solenoid
assembly.
Go to “Inverter
solenoid
assembly
removal” on
page 4-181.
Replace the
connection.
12 Check the registration motor (forward or reverse) test.
Perform the registration motor test.
Open the ADF left cover assembly.
Remove the ADF rear cover. Go to “ADF rear cover
removal” on page 4-173.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch Scanner Motor Tests.
4. Touch ADF registration drv mtr.
5. Touch Forward or reverse.
Does the ADF registration motor operate properly?
Go to step 14. Go to step 13.
13 Check the ADF registration motor for connection.
Is the above motor connected properly?
Replace the
ADF
registration
motor.
Go to “ADF
registration
motor
removal” on
page 4-209.
Replace the
connection.
Step Check Yes No