4-324 MFP Service Manual
7500-432, -632, and -832
1. Remove the exit 2 unit assembly. See “Exit 2 unit assembly removal” on page 4-322.
2. Open the exit 2 unit assembly.
3. Remove two screws securing the upper guide assembly (A) to the exit 2 unit assembly.
4. Remove the upper guide assembly (A).
Note: The exit 2 left door handle (B) may become detached.
5. Remove the exit 2 left door handle (B) from the upper guide assembly (A).
6. Remove the spring (C) from the upper guide assembly (A).
Note: After reinstalling the upper guide assembly (A), ensure the exit 2 left door handle (B) operates
freely.