ACCESS PROCEDURE
4-10
C231/C237/C238 SM
Change Adjustment Values or Modes
1. After entering the desired SP mode number and pressing the
Enter (#)key
, the
current value or mode will be displayed on the LCD (at the end of the second
line).
2. Enter the desired value or mode using the
number keys
(listed in the service
program table).
NOTE:
Use the
Memory/ Class key
to toggle between + and -.
3. Press the
Enter (#) key
to store the desired value or mode.
4. To cancel the SP mode, press the
Clear Modes key
.