SP TABLE (SP 7-XXX)
C267 5-18 SM
5.8 MEMORY CLEAR
5.8.1 SP TABLE (SP 7-XXX)
No. Menu Items
1 Factory settings clear
3 Total counter clear
4 Jam/Error data clear
5.8.2 SP7-1: FACTORY SETTINGS CLEAR
This resets all SP and User tool settings except for the following SP and User tool
numbers.
• User tool 1: Counter Display (Masters and Prints)
• User tool 2-4: mm/inch
• User tool 2-5: Language on LCD
• User tool 2-6: Date/Time
• SP2-4: Destination code
• SP2-20: Destination setting
• SP2-80: Auto off at unusual voltage
• SP3-3: Input serial number
• SP6-All: Adjustments
5.8.3 SP7-3: TOTAL COUNTER CLEAR
This resets the following SP numbers
• SP1-1 Total master counter
• SP1-20 Total print counter
NOTE: The counters for “User tool 1: Counter Display” are unresetable counter