EasyManua.ls Logo

Rohde & Schwarz RTP044 - Page 1617

Rohde & Schwarz RTP044
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTP
1617User Manual 1337.9952.02 ─ 12
BUS<m>:CAN:DATA:THReshold <Threshold>
Sets a user-defined threshold value.
Alternatively, you can set the threshold according to the signal technology with
BUS<m>:CAN:TECHnology.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<Threshold> Range: -12 to 12
Increment: 0.1
*RST: 0
Default unit: V
BUS<m>:CAN:TECHnology
<Technology>
Sets the threshold voltage as defined for various signal technologies.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<Technology> V25 | V3 | V2 | V0 | MANual
V25
2.5 Volt (CMOS 5.0 V)
V3
3.0 Volt (CAN_H HS / CAN_L LS)
V2
2.0 Volt (CAN_L HS / CAN_H LS)
V0
Ground
MANual
Manual setting of user-defined values with BUS<m>:CAN:DATA:
THReshold.
*RST:
V25
BUS<m>:CAN:BITRate <Bitrate>
For CAN buses, the "Bit rate" sets the number of transmitted bits per second.
For CAN FD buses, this parameter is called "Arbitration rate" and sets the bit rate of
the arbitration phase.
The maximum bit rate for High Speed CAN is 1 Mbit/s. The bit rate is uniform and fixed
for a given CAN or CAN FD bus.
Protocols

Table of Contents

Other manuals for Rohde & Schwarz RTP044

Related product manuals