Remote control commands
R&S
®
RTP
1620User Manual 1337.9952.02 ─ 12
Parameters:
<FlexDatTimeSeg2>
<TimeSeg2>
Time quanta
Range: 1 to 21
Increment: 1
*RST: 3.4
BUS<m>:CAN:FDATa:JWIDth <FlexDatJumpWdt>
BUS<m>:CAN:JWIDth <JumpWidth>
Defines the maximum number of time quanta for phase correction. Time segment1
may be lengthened or Time segment2 may be shortened due to resynchronization.
Resynchronization corrects the phase error of an edge caused by the drift of the oscil-
lators.
For CAN FD signals, this setting defines the synchronization of the arbitration phase.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<JumpWidth> Time quanta
Range: 1 to 4, available maximum depends on the num-
ber of segments and the sample point
Increment: 1
*RST: 1
22.17.6.2 Trigger
The trigger suffix <m> is always 1 and can be omitted. It selects the trigger event: Only
the A-trigger is available for triggering on serial buses.
To trigger on a serial bus, make sure that:
●
TRIGger<m>:SOURce[:SELect] is set to SBUS.
●
The sources of the serial bus are channel signals: use BUS<m>:...:SOURce
commands.
●
Decoding is enabled: BUS<m>[:STATe] is set to ON.
TRIGger<m>:CAN:TYPE.............................................................................................. 1621
TRIGger<m>:CAN:FDATa:STANdard............................................................................. 1622
TRIGger<m>:CAN:FTYPe.............................................................................................1622
TRIGger<m>:CAN:ITYPe..............................................................................................1622
TRIGger<m>:CAN:ICONdition.......................................................................................1623
TRIGger<m>:CAN:IMIN................................................................................................1623
TRIGger<m>:CAN:IMAX...............................................................................................1623
TRIGger<m>:CAN:FDATa:FDF......................................................................................1623
TRIGger<m>:CAN:FDATa:BRS..................................................................................... 1624
TRIGger<m>:CAN:FDATa:ESI.......................................................................................1624
TRIGger<m>:CAN:DCONdition..................................................................................... 1624
TRIGger<m>:CAN:DMIN.............................................................................................. 1624
Protocols