Remote control commands
R&S
®
RTP
1635User Manual 1337.9952.02 ─ 12
BUS<m>:CAN:FRAMe<n>:BSEPosition?
Returns the location of a bit stuffing error.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the frame.
Return values:
<BitStuffErrorPos> Time when the error occured
Range: 0 to 5000
*RST: 0
Usage: Query only
BUS<m>:CAN:FRAMe<n>:FERCause?
Returns information on a form error, if the frame status query returned a FORM error.
See also: BUS<m>:CAN:FRAMe<n>:STATus? on page 1629
Suffix:
<m>
.
1..4
<n> *
Return values:
<FormErrorCause> NONE | CRCDerror | ACKDerror | FSBE | RESerror
CRCD = CRC delimiter error
ACKD = ACK delimiter error
FSBE = Fixed stuff bit error (CAN-FD ISO only)
RESE = Reserved bit error
*RST: NONE
Usage: Query only
BUS<m>:CAN:FRAMe<n>:SDEXport?
Returns the symbolic data of the frame in export format.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the frame.
Return values:
<SymbolicData>
Usage: Query only