Remote control commands
R&S
®
RTP
2212User Manual 1337.9952.02 ─ 12
Parameters:
<Width> Range: 200E-12 to 10000
Increment: 200E-9
*RST: 5E-9
Default unit: s
Usage: Asynchronous command
TRIGger<m>:PARallel:WIDTh:DELTa <WidthDelta>
Defines a range around the given width value. the setting is relevant if TRIGger<m>:
PARallel:WIDTh:RANGe is set to WITHin or OUTSide. The width is set with
TRIGger<m>:PARallel:WIDTh:WIDTh.
Parameters:
<WidthDelta> Range: 0 to 432
Increment: 600E-12
*RST: 0
Default unit: s
Usage: Asynchronous command
22.18.4.4 Timeout trigger
See also:
TRIGger<m>:PARallel:TIMeout:EXPRession[:DEFine] on page 2210
TRIGger<m>:PARallel:TIMeout:RANGe......................................................................... 2212
TRIGger<m>:PARallel:TIMeout:TIME.............................................................................2213
TRIGger<m>:PARallel:TIMeout:RANGe <TimeoutMode>
Sets the state condition.
Parameters:
<TimeoutMode> HIGH | LOW | EITHer
HIGH
The level of a digital channel stays above the threshold, or the
logical expression for LOGic trigger source is true.
LOW
The level of a digital channel stays below the threshold, or the
logical expression for LOGic trigger source is false.
EITHer
The signal state remains unchanged.
*RST: HIGH
Usage: Asynchronous command