VDR Installation & Commissioning Checklist, Rev 1.2
2d. OAU is functioning properly
Audible alarm is functioning correctly.
All keypad buttons are functioning correctly.
LCD Display is displaying appropriate alarms.
Alarm display shows status clear when alarm clears.
Download to DMM internal drive is working via appropriate keypad press and
confirmation of the download.
Technician Initialed: ______________________ Date: __________
2e. FRM Recording is configured
Check that breaker is switched on.
The FRM is formatted as described in the Installation manual.
The FRM is enabled and set to correct capsule type in the VDRPARAMS.INI file.
Configuration file is being sent to the capsule.
Data can be downloaded from the capsule using the download software.
All 12 hours of required IMO data is present.
Technician Initialed: ______________________ Date: __________
2f. Second FRM Recording is configured (Dual Capsule configuration)
Check that breaker is switched on.
The FRM is formatted as described in the Installation manual.
The FRM is enabled and set to correct capsule type in the VDRPARAMS.INI file.
Configuration file is being sent to the capsule.
Data can be downloaded from the capsule using the download software.
All 12 hours of required IMO data is present.
VDR Installation Manual 06/10/2008
6