Appendix 3: VDRPARAMS.INI File, Rev. 1.2
VDR-100G3/G3S Installation Manual 18/01/2009
3
L3 HVR/SVR Fixed Capsule
If the capsule is an L3 HVR/SVR Fixed capsule, the configuration information is read from the
following fields: L3HVR-serverPort, L3HVR-IP, L3HVR-numStreams and L3HVR-
streamNameX, where X varies from 1 to L3HVR-numStreams.
The data types to be written to each stream are defined in L3HVR-streamTypeX, where X varies
from 1 to L3HVR-numStreams.
To report internal capsule errors to the alarm unit, enable the L3HVR-errorChecking field. To
compress the NMEA data prior to sending it to the capsule, enable the L3HVR-compressNMEA
field.
Jotron Float-Free Capsule
For a Jotron Float-Free capsule, the configuration information is read from the following fields:
NetworkHVR-IP, NetworHVR-compressNMEA, NetworkHVR-DriveLetter, and NetworkHVR-
DataLocation.
The VDR_Record application will map a drive to the Jotron Float-Free internal hard disk using the
letter specified by NetworkHVR-DriveLetter and create a folder name described by
NetworkHVR-DataLocation to store the VDR data. To compress the NMEA data prior to
sending it to the capsule, enable NetworkHVR-compressNMEA field.
The Jotron Float-Free capsule may also be configured as a secondary FRM, in which case the
NetworkHVR-IP would be configured as 200.200.200.37.
Rutter-ACR Float-Free Capsule
The Rutter-ACR Float-Free SFRM capsule is configured based on the flowing fields:
CACRFFMC-IP, CACRFFMC-serverWritePort, CACRFFMC-serverReadPort, and
CACRFFMC-serverConfigPort. The Rutter-ACR Float-Free capsule may also be configured as
a secondary FRM, in which case the CARFFMC-IP would be configured as 200.200.200.100.
Rutter Fixed Capsule
For a Rutter
capsule the IP configuration information is read from the RutterFixed-IP field of the
vdrparams.ini file.
The VDR_Record application will map a drive to the Rutter internal hard disk using the letter
specified by RutterFixed-DriveLetter. To compress the NMEA data prior to sending it to the
capsule, enable RutterFixed-compressNMEA.