EasyManua.ls Logo

Siemens SINAMICS G120D CU240D-2 DP - r0630[0...n] Mot_temp_mod ambient temperature; Mod T_ambient; r0631[0...n] Mot_temp_mod stator iron temperature; Mod T_stator; r0632[0...n] Mot_temp_mod stator winding temperature; Mod T_winding; r0633[0...n] Mot_temp_mod rotor temperature; Mod rotor temp

Siemens SINAMICS G120D CU240D-2 DP
980 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
117
2 Parameters
2.2 List of parameters
Description: Displays the ambient temperature of the motor temperature model (models 2 and 3).
Description: Displays the stator iron temperature of the motor temperature model (models 2 and 3).
Note: For motor temperature model 1 (p0612.0 = 1), this parameter is not valid:
Description: Displays the stator winding temperature of the motor temperature model.
Dependency: Refer to: F07011, A07012, A07910
Description: Displays the rotor temperature of the motor temperature model (models 2 and 3).
Note: For motor temperature model 1 (p0612.0 = 1), this parameter is not valid:
Description: The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
The parameter weights the unsaturated component of the quadrature axis flux function.
Description: The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
r0630[0...n] Mot_temp_mod ambient temperature / Mod T_ambient
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2006 Dyn. index: MDS
Unit group: 21_1 Unit selection: p0505 Func. diagram: 8018
Min Max Factory setting
- [°C] - [°C] - [°C]
r0631[0...n] Mot_temp_mod stator iron temperature / Mod T_stator
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2006 Dyn. index: MDS
Unit group: 21_1 Unit selection: p0505 Func. diagram: 8018
Min Max Factory setting
- [°C] - [°C] - [°C]
r0632[0...n] Mot_temp_mod stator winding temperature / Mod T_winding
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2006 Dyn. index: MDS
Unit group: 21_1 Unit selection: p0505 Func. diagram: 8017, 8018
Min Max Factory setting
- [°C] - [°C] - [°C]
r0633[0...n] Mot_temp_mod rotor temperature / Mod rotor temp
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2006 Dyn. index: MDS
Unit group: 21_1 Unit selection: p0505 Func. diagram: 8018
Min Max Factory setting
- [°C] - [°C] - [°C]
p0634[0...n] Q flux flux constant unsaturated / PSIQ KPSI UNSAT
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(3), U, T Scaling: - Dyn. index: MDS
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.000 [Vsrms] 100.000 [Vsrms] 0.000 [Vsrms]
p0635[0...n] Q flux quadrature axis current constant unsaturated / PSIQ KIQ UNSAT
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(3), U, T Scaling: - Dyn. index: MDS
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.00 [Arms] 10000.00 [Arms] 0.00 [Arms]