SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
75
2 Parameters
2.2 List of parameters
Description: Displays the rated motor stator resistance at rated temperature (total of p0625 and p0627).
Dependency: Refer to: p0627
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Displays the motor rotor resistance at an ambient temperature p0625.
Dependency: Refer to: p0625
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Displays the nominal rotor resistance of the motor at the rated temperature.
The rated temperature is the sum of p0625 and p0628.
Dependency: Refer to: p0628
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Displays the stator leakage inductance of the motor including the motor reactor (p0233).
Description: Displays the stator longitudinal inductance of the synchronous motor including the motor reactor (p0233).
r0373[0...n] Motor rated stator resistance / Mot R_stator rated
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: MDS
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
r0374[0...n] Motor rotor resistance cold / Mot R_r cold
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: MDS
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
r0376[0...n] Rated motor rotor resistance / Mot rated R_rotor
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: MDS
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
r0377[0...n] Motor leakage inductance total / Mot L_leak total
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: MDS
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [mH] - [mH] - [mH]
r0378[0...n] Motor stator inductance d axis / Mot L_stator d
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: MDS
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [mH] - [mH] - [mH]