2 Parameters
2.2 List of parameters
SINAMICS G120D
362 List Manual (LH14), 01/2016, A5E33842313
Description: Sets a block number.
-1: Invalid block number. These blocks are not taken into account.
0 ... 15: valid block number.
Dependency: The number of indices depends on p2615.
Refer to: p2615, p2617, p2618, p2619, p2620, p2621, p2622, p2623, p2624
Description: Sets the target position for the traversing block.
Dependency: The number of indices depends on p2615.
Refer to: p2615, p2616, p2618, p2619, p2620, p2621, p2622, p2623, p2624
Note: The target position is approached in either relative or absolute terms depending on p2623.
Description: Sets the velocity for the traversing block.
Dependency: The number of indices depends on p2615.
Refer to: p2615, p2616, p2617, p2619, p2620, p2621, p2622, p2623, p2624, p2646
Note: The velocity can be influenced using the velocity override (p2646).
Description: Sets the acceleration override for the traversing block.
The override refers to the maximum acceleration (p2572).
Dependency: The number of indices depends on p2615.
Refer to: p2572, p2615, p2616, p2617, p2618, p2620, p2621, p2622, p2623, p2624
p2616[0...n] EPOS traversing block block number / Trav_blk, blkNo.
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: Integer16
Can be changed: U, T Scaling: - Dyn. index: p2615
Unit group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
-1 15 -1
p2617[0...n] EPOS traversing block position / Trav_block pos
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: Integer32
Can be changed: U, T Scaling: - Dyn. index: p2615
Unit group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
-2147482648 [LU] 2147482647 [LU] 0 [LU]
p2618[0...n] EPOS traversing block velocity / Trav_block v
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: Integer32
Can be changed: U, T Scaling: - Dyn. index: p2615
Unit group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
1 [1000 LU/min] 40000000 [1000 LU/min] 600 [1000 LU/min]
p2619[0...n] EPOS traversing block acceleration override / Trav_block a_over
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: p2615
Unit group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
1.0 [%] 100.0 [%] 100.0 [%]