2 Parameters
2.2 List of parameters
Description: Displays the characteristics (A5E number and versions) of the power unit.
[0]: A5E number xxxx (A5Exxxxyyyy)
[1]: A5E number yyyy (A5Exxxxyyyy)
[2]: File version (logistic)
[3]: File version (fixed data)
[4]: File version (calib data)
Description: For service personnel only.
Description: Displays the measured Control Unit temperature.
An appropriate message is output when 87 °C is exceeded.
Index: [0] = Actual measured value
[1] = Maximum measured value
Dependency: Refer to: A01009
Note: The value of -200 indicates that there is no measuring signal.
For r3960[0]:
Displays the currently measured Control Unit temperature.
For r3960[1]:
Displays the highest measured Control Unit temperature. This value is saved on the module in a non-volatile fashion.
Description: Displays the status word for the drive unit.
r3930[0...4] Power unit EEPROM characteristics / PU characteristics
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
p3950 Service parameter / Serv par
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: C, U, T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
r3960[0...1] Control Unit temperature measured / CU temp measured
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2006 Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [°C] - [°C] - [°C]
r3974 Drive unit status word / Drv_unit ZSW
Access level: 1 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Software reset active Yes No -
01 Writing of parameters disabled as
parameter save in progress
Yes No -
02 Writing of parameters disabled as macro is
running
Yes No -