2 Parameters
2.2 List of parameters
Description: For the manual mode: Display of STW1 (control word 1) entered at the BOP/ IOP.
Description: For the manual mode: Display of the speed setpoint entered at the BOP/ IOP.
Description: For the manual mode: Setting of the signal sources for STW1 (control word 1).
r8540.0...15 BO: STW1 from BOP/IOP in the manual mode / STW1 OP
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 ON/OFF1 Yes No -
01 OC / OFF2 Yes No -
02 OC / OFF3 Yes No -
03 Reserved Yes No -
04 Reserved Yes No -
05 Reserved Yes No -
06 Reserved Yes No -
07 Acknowledge fault Yes No -
08 Jog bit 0 Yes No 3030
09 Jog bit 1 Yes No 3030
10 Reserved Yes No -
11 Direction reversal (setpoint) Yes No -
12 Reserved Yes No -
13 Reserved Yes No -
14 Reserved Yes No -
15 Reserved Yes No -
r8541 CO: Speed setpoint from BOP/IOP in the manual mode / N_set OP
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Dyn. index: -
Unit group: 3_1 Unit selection: p0505 Func. diagram: -
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
p8542[0...15] BI: Active STW1 in the BOP/IOP manual mode / STW1 act OP
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - [0] 8540.0
[1] 8540.1
[2] 8540.2
[3] 8540.3
[4] 8540.4
[5] 8540.5
[6] 8540.6
[7] 8540.7
[8] 8540.8
[9] 8540.9
[10] 8540.10
[11] 8540.11
[12] 8540.12
[13] 8540.13
[14] 8540.14
[15] 8540.15