SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
515
2 Parameters
2.2 List of parameters
Description: Display parameter for output quantity Y of instance AVA 0 of the absolute value generator with sign evaluation.
Description: Display parameter for signal SN that the input quantity X of instance AVA 0 of the absolute value generator with sign
evaluation is negative.
X < 0.0 => SN = 1
Description: Setting parameter for the run-time group in which instance AVA 0 of the absolute value generator with sign
evaluation is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance AVA 0 within the run-time group set in p20131.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of the input quantity X of instance AVA 1 of the absolute value generator with sign evaluation.
r20129 CO: AVA 0 output Y / AVA 0 output Y
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7224
Min Max Factory setting
- - -
r20130 BO: AVA 0 input negative SN / AVA 0 input neg SN
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7224
Min Max Factory setting
- - -
p20131 AVA 0 run-time group / AVA 0 RTG
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7224
Min Max Factory setting
5 9999 9999
p20132 AVA 0 run sequence / AVA 0 RunSeq
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7224
Min Max Factory setting
0 32000 340
p20133 CI: AVA 1 input X / AVA 1 input X
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7224
Min Max Factory setting
- - 0