EasyManua.ls Logo

Siemens SINAMICS G120D CU240D-2 DP - Fig. 3-66 2823 - SSM (Safe Speed Monitor)

Siemens SINAMICS G120D CU240D-2 DP
980 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
671
3 Function diagrams
3.9 Safety Integrated Extended Functions
Fig. 3-66 2823 – SSM (Safe Speed Monitor)
r9714
SI Mtn diag v P1 [rpm]
- 2823 -
Function diagram
87654321
fp_2823_97_58.vsd
Safety Integrated Extended Functions
SINAMICS G120D
09.12.2015 V4.7.6
SSM (Safe Speed Monitor)
1
0
SI Mtn SSM filt P1
0.00 ... 100.00 [ms]
p9545 (0.00)
SI Mtn SSM filt P2
0.00 ... 100000.00 [µs]
p9345 (0.00)
SI Mtn SSM v_limP1
0.00 ... 100000.00 [rpm]
p9546 (20.00)
SI Mtn SSM hyst P1
0.0010 ... 500.0000 [rpm]
p9547 (10.0000)
SI Mtn SSM v_limP2
0.00 ... 100000.00 [rpm]
p9346 (20.00)
SI Mtn SSM Hyst P2
0.0010 ... 500.0000 [rpm]
p9347 (10.0000)
SI Mtn int stat P1
r9722
r9722
.15
0
1
0
1
[0]
1 = SSM
(Speed below limit value)
[2840.5]
SI Mtn enable CU
p9501.16
SI Mtn enable P2
p9301.16