2 Parameters
2.2 List of parameters
SINAMICS G120D
224 List Manual (LH14), 01/2016, A5E33842313
Description: Sets the signal source for the scaling of the upper torque limit in p1522.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Danger: For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Negative values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source for the scaling of the lower torque limit in p1523.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Danger: For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Positive values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source for the scaling of the lower torque limit in p1523.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Danger: For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Positive values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the power limit when motoring.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p0500, p1531
Note: The power limit is limited to 300% of the rated motor power.
p1528[0...n] CI: Torque limit upper scaling / M_max upper scal
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 4 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: CDS, p0170
Unit group: - Unit selection: - Func. diagram: 6630
Min Max Factory setting
- - 2686[0]
p1529[0...n] CI: Torque limit lower scaling / M_max lower scal
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level: 4 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: CDS, p0170
Unit group: - Unit selection: - Func. diagram: 6630
Min Max Factory setting
- - 1525[0]
p1529[0...n] CI: Torque limit lower scaling / M_max lower scal
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 4 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: CDS, p0170
Unit group: - Unit selection: - Func. diagram: 6630
Min Max Factory setting
- - 2686[1]
p1530[0...n] Power limit motoring / P_max mot
Access level: 2 Calculated: p0340 = 1,3,5 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Unit group: 14_5 Unit selection: p0505 Func. diagram: 6640
Min Max Factory setting
0.00 [kW] 100000.00 [kW] 0.00 [kW]