Siemens SINAMICS G120D CU240D-2 DP - p2510[0...3] BI: LR selecting measuring probe evaluation; MT_eval select; p2511[0...3] BI: LR measuring probe evaluation edge; MT_eval edge; p2512[0...3] BI: LR pos. actual value preprocessing activate corr. value (edge); ActVal_prepCorrAct

Siemens SINAMICS G120D CU240D-2 DP
980 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G120D
334 List Manual (LH14), 01/2016, A5E33842313
Description: Sets the signal source to select the measuring probe.
1 signal = measuring probe 2 is activated for BI: p2509 = 0/1 edge.
0 signal = measuring probe 1 is activated for BI: p2509 = 0/1 edge.
Index: [0] = Position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency: Refer to: p2502, p2509, p2511
Note: The following BICO interconnection is established as standard:
BI: p2509[0] = r2684.1
The measuring probe is selected at the 0/1 signal transition at r2684.1 (flying referencing active).
Description: Sets the signal source for the edge evaluation of the measuring probe.
1 signal = falling edge of the measuring probe (p2510) is activated for BI: p2509 = 0/1 edge.
0 signal = rising edge of the measuring probe (p2510) is activated for BI: p2509 = 0/1 edge.
Index: [0] = Position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency: Refer to: p2502, p2509, p2510
Description: Sets the signal source for the function "activate position actual value preprocessing, corrective value (edge)".
0/1 signal:
The correction value available via CI: p2513 is activated.
Index: [0] = Position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency: Refer to: p2502, p2513, r2684
p2510[0...3] BI: LR selecting measuring probe evaluation / MT_eval select
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3615, 4010
Min Max Factory setting
- - 0
p2511[0...3] BI: LR measuring probe evaluation edge / MT_eval edge
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3615, 4010
Min Max Factory setting
- - 0
p2512[0...3] BI: LR pos. actual value preprocessing activate corr. value (edge) /
ActVal_prepCorrAct
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 4010, 4015
Min Max Factory setting
- - [0] 2684.7
[1] 0
[2] 0
[3] 0