2 Parameters
2.2 List of parameters
Note: If, after the fixed stop is reached, the end stop shifts in either the positive or negative direction by more than the value
set here, then BO: r2526.5 is set to 1 and an appropriate message is output.
Description: Sets the signal source for the feedback signal "fixed stop reached".
BI: p2637 = 1 signal
Fixed stop is reached.
BI: p2637 = 0 signal
Fixed stop is not reached.
Dependency: Refer to: r2526, p2634
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: The identification of "fixed stop reached" is, for the factory setting, dependent on the signal BO: r2526.4 (fixed stop
reached). This signal is influenced via p2634 (EPOS fixed stop, maximum following error).
Description: Sets the signal source for the feedback signal "fixed stop outside the monitoring window".
BI: p2638 = 1 signal
Fixed stop is located outside the monitoring window.
BI: p2638 = 0 signal
Fixed stop is inside the monitoring window.
Dependency: Refer to: r2526, p2635
Note: The identification of "fixed stop outside the monitoring window" is, for the factory setting, dependent on signal BO:
r2526.5 (fixed stop outside window). This signal is influenced via p2635 (EPOS fixed stop monitoring window).
Description: Sets the signal source for the feedback signal "torque limit reached" when traversing to fixed stop.
BI: p2639 = 1 signal
Torque limit is reached.
BI: p2639 = 0 signal
Torque limit is not reached.
Dependency: Refer to: r1407
Note: The feedback signal from "torque limit reached" is, for the factory setting, dependent on the signal BO: r1407.7
(torque limit reached).
p2637 BI: EPOS fixed stop reached / Fixed stop reached
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3616, 3617
Min Max Factory setting
- - 2526.4
p2638 BI: EPOS fixed stop outside the monitoring window / Fixed stop outside
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3616, 3617
Min Max Factory setting
- - 2526.5
p2639 BI: EPOS torque limit reached / M_limit reached
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
- - 1407.7