EasyManua.ls Logo

Siemens SINAMICS G120D CU240D-2 DP - Fig. 3-130 6722 - Field weakening characteristic, flux setpoint (ASM, p0300 = 1)

Siemens SINAMICS G120D CU240D-2 DP
980 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
741
3 Function diagrams
3.15 Vector control
Fig. 3-130 6722 – Field weakening characteristic, flux setpoint (ASM, p0300 = 1)
- 6722 -
Function diagram
87654321
fp_6722_97_55.vsd
Vector control
SINAMICS G120D
09.12.2015 V4.7.6
Field weakening characteristic, flux setpoint (ASM, p0300 = 1)
<1>
For vector control without encoder (SLVC).
0.9
1
0
MIN
<0.3 s
f
y
[6060.5]
[6723.1]
[6640.3]
[6723.1]
[2526.2]
U_output max [Vrms]
r0071
Field weak T_smth
0 ... 20000 [ms]
p1584 [D] (0)
Flex setp
50.0 ... 200.0 [%]
p1570 [D] (100.0)
ZSW cl-loop ctrl
r0056
r0056
Efficiency opt.
0 ... 100 [%]
p1580 [D] (0)
Mot T_rotor/T_Dd [ms]
r0384 [D]
M_set static
-200.0 ... 200.0 [%]
p1610 [D] (50.0)
M_suppl_accel
0.0 ... 200.0 [%]
p1611 [D] (30.0)
r1508
M_set bef. M_suppl [Nm]
Mot I_mag_rtd act [Arms]
r0331 [D]
I_set T_smooth
4 ... 10000 [ms]
p1616 [D] (40)
.2
ZSW cl-loop ctrl
r0056
r0056
Flux setp T_smth
4 ... 5000 [ms]
p1582 [D] (15)
Flux setp smooth [%]
r1583
Field weakening characteristic
Efficiency optimization
Id_set
calculation
Flux setpoint
calculation
Magnetization control
Id current limit
ASM: Asynchronmotor (induction motor)
Mot t_excitation
0.000 ... 20.000 [s]
p0346 [D] (0.000)
MotMod status
r1751
r0067
I_outp max [Arms]
r0063
n_act [rpm]
[0]
1 = Flux setpoint soft starting active
1 = Flux build-up control active
1 = Quick magnetizing
Quick magnetizing active
[6723.8]
[6730.4]
<1>
–
+
+
.8 [2526.2]
.4
p1401
.0
p1401
p1401
.6
[4715.7]
1 = Magnetization completed
1 = Field weakening active
[6723.3]
Field weak scal
80.0 ... 120.0 [%]
p1586 [D] (100.0)

Table of Contents

Related product manuals