SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
701
3 Function diagrams
3.12 Basic positioner (EPOS)
Fig. 3-93 3618 – Direct setpoint input / MDI mode, dynamic values
- 3618 -
Function diagram
87654321
fp_3618_97_55.vsd
Basic positioner (EPOS)
G120D CU250D-2
09.12.2015 V4.7.6
Direct setpoint input / MDI mode, dynamic values
[3620.1]
[3620.1]
[3620.1]
[3620.1]
100 %
0.1 %
100 %
0.1 %
MDI s_set
(2690[0])
p2642
MDI v_set
(2691[0])
p2643
MDI a_over
(2692[0])
p2644
MDI -a_over
(2693[0])
p2645
Pos fixed value
-2147482648 ... 2147482647 [LU]
p2690 (0)
v fixed value
1 ... 40000000 [1000 LU/min]
p2691 (600)
a_over fixed val
0.100 ... 100.000 [%]
p2692 (100.000)
-a_over fixed val
0.100 ... 100.000 [%]
p2693 (100.000)
1