2 Parameters
2.2 List of parameters
Description: Sets the signal source to select the traversing block, bit 1.
Dependency: Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2627, p2628
Description: Sets the signal source to select the traversing block, bit 2.
Dependency: Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2626, p2628
Description: Sets the signal source to select the traversing block, bit 3.
Dependency: Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2626, p2627
Description: Sets the signal source for "activating traversing task".
BI: p2631 = 0/1 signal
The traversing task, selected using BI: p2625 ... p2630, is started.
Dependency: Refer to: p2625, p2626, p2627, p2628, p2640, p2641
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: To start a traversing block, the axis must be referenced (r2684.11 = 1).
The status signal r2684.12 = 0/1 signal is used for acknowledgment.
A traversing task can be influenced using the following signals:
- intermediate stop via BI: p2640.
- reject traversing task via BI: p2641.
p2626 BI: EPOS traversing block selection bit 1 / Trav_blk sel bit 1
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3616, 3640
Min Max Factory setting
- - 0
p2627 BI: EPOS traversing block selection bit 2 / Trav_blk sel bit 2
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3616, 3640
Min Max Factory setting
- - 0
p2628 BI: EPOS traversing block selection bit 3 / Trav_blk sel bit 3
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3616, 3640
Min Max Factory setting
- - 0
p2631 BI: EPOS activate traversing task (0 -> 1) / Trav_task act
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3616, 3625
Min Max Factory setting
- - 0