Siemens SINAMICS G120D CU240D-2 DP - p2626 BI: EPOS traversing block selection bit 1; Trav_blk sel bit 1; p2627 BI: EPOS traversing block selection bit 2; Trav_blk sel bit 2; p2628 BI: EPOS traversing block selection bit 3; Trav_blk sel bit 3; p2631 BI: EPOS activate traversing task (0 -> 1); Trav_task act

Siemens SINAMICS G120D CU240D-2 DP
980 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
365
2 Parameters
2.2 List of parameters
Description: Sets the signal source to select the traversing block, bit 1.
Dependency: Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2627, p2628
Description: Sets the signal source to select the traversing block, bit 2.
Dependency: Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2626, p2628
Description: Sets the signal source to select the traversing block, bit 3.
Dependency: Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2626, p2627
Description: Sets the signal source for "activating traversing task".
BI: p2631 = 0/1 signal
The traversing task, selected using BI: p2625 ... p2630, is started.
Dependency: Refer to: p2625, p2626, p2627, p2628, p2640, p2641
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: To start a traversing block, the axis must be referenced (r2684.11 = 1).
The status signal r2684.12 = 0/1 signal is used for acknowledgment.
A traversing task can be influenced using the following signals:
- intermediate stop via BI: p2640.
- reject traversing task via BI: p2641.
p2626 BI: EPOS traversing block selection bit 1 / Trav_blk sel bit 1
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3616, 3640
Min Max Factory setting
- - 0
p2627 BI: EPOS traversing block selection bit 2 / Trav_blk sel bit 2
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3616, 3640
Min Max Factory setting
- - 0
p2628 BI: EPOS traversing block selection bit 3 / Trav_blk sel bit 3
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3616, 3640
Min Max Factory setting
- - 0
p2631 BI: EPOS activate traversing task (0 -> 1) / Trav_task act
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3616, 3625
Min Max Factory setting
- - 0