Fig. 3-37 2477 – PROFIdrive - AKTSATZ status word interconnection
- 2477 -
Function diagram
87654321
fp_2477_97_55.vsd
PROFIdrive (PROFIBUS/PROFINET), EtherNet/IP
CU250D-2 DP-F/PN-F
09.12.2015 V4.7.6
PROFIdrive - AKTSATZ status word interconnection
SATZANW.0
SATZANW.1
SATZANW.2
SATZANW.3
SATZANW.4
SATZANW.5
SATZANW.6
SATZANW.8
SATZANW.9
SATZANW.11
SATZANW.12
SATZANW.13
SATZANW.14
SATZANW.15
SATZANW.7
SATZANW.10
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Signal targets for AKTSATZ (positioning mode)
Signal Meaning
Interconnection
parameters
[Function diagram]
internal control word
[Function diagram]
signal target
Inverted
1 = Active traversing block, bit 0
Reserved
Reserved
Reserved
Reserved
1 = Active traversing block, bit 1
Reserved
Reserved
Reserved
Reserved
Reserved
1 = MDI active
0 = MDI inactive
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1 = Active traversing block, bit 2
1 = Active traversing block, bit 3
<1>
-
-
-
-
-
-
r2670.2
r2670.3
r2670.15
r2670.0
r2670.1
-
-
<1>
Used in telegrams 7, 9, 110.
Reserved
Reserved