2 Parameters
2.2 List of parameters
SINAMICS G120D
406 List Manual (LH14), 01/2016, A5E33842313
Description: Sets the configuration for the motor temperature sensor.
Dependency: Refer to: p0601
Notice: For bit 00:
If the short-circuit monitoring is de-activated, this can damage the motor when a short-circuit occurs.
Note: For bit 00:
The bit is only active for p0601 = 1.
Description: Displays the encoder diagnostics for the PROFIdrive interface.
Description: Trace functionality for OEM encoder manufacturers.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Description: Sets the mode to reset the actual value in XIST_ERW (CO: r4653).
Value: 0: Inactive
1: Reset with zero mark
2: Reset with BICO
3: Reset with selected zero mark
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency: Refer to: r4653, r4654, p4655
Note: The absolute value is only valid after passing the zero mark.
If value = 1:
The value in XIST1_ERW is reset when passing every zero mark.
If value = 2:
The value in XIST1_ERW is reset with a 0/1 edge via binector input p4655.
p4621[0...n] Motor temperature sensor configuration / Mot_temp_sens cfg
Access level: 2 Calculated: - Data type: Unsigned32
Can be changed: C(3), T Scaling: - Dyn. index: MDS
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 De-activate PTC short-circuit monitoring Yes No 8016
r4640[0...95] Encoder diagnostics state machine / Enc diag stat_ma
Access level: 4 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
p4641[0...2] OEM encoder diagnostic signal selection / OEM enc diag sel
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: U, T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 65535 0
p4652[0...2] XIST1_ERW reset mode / XIST1_ERW res mode
Access level: 3 Calculated: - Data type: Integer16
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 4750
Min Max Factory setting
0 3 0