SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
121
2 Parameters
2.2 List of parameters
Description: Displays the status of the digital inputs.
Dependency: Refer to: r0723
Note: DI: Digital Input
Description: Displays the inverted status of the digital inputs.
Dependency: Refer to: r0722
Note: AI: Analog Input
DI: Digital Input
Description: Displays the inverted status of the digital inputs.
Dependency: Refer to: r0722
Note: DI: Digital Input
r0722.0...5 CO/BO: CU digital inputs status / CU DI status
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 2 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2201, 2210, 2256,
2810
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X07.4) High Low -
01 DI 1 (X07.2) High Low -
02 DI 2 (X08.4) High Low -
03 DI 3 (X08.2) High Low -
04 DI 4 (X09.4) High Low -
05 DI 5 (X09.2) High Low -
r0723.0...12 CO/BO: CU digital inputs status inverted / CU DI status inv
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level: 2 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2201, 2210, 2256
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X07.4) High Low -
01 DI 1 (X07.2) High Low -
02 DI 2 (X08.4) High Low -
03 DI 3 (X08.2) High Low -
04 DI 4 (X09.4) High Low -
05 DI 5 (X09.2) High Low -
11 DI 11 (X10.3) AI 0 High Low -
12 DI 12 (X10.4) AI 1 High Low -
r0723.0...5 CO/BO: CU digital inputs status inverted / CU DI status inv
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 2 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2201, 2210, 2256
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X07.4) High Low -
01 DI 1 (X07.2) High Low -
02 DI 2 (X08.4) High Low -
03 DI 3 (X08.2) High Low -
04 DI 4 (X09.4) High Low -
05 DI 5 (X09.2) High Low -