SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
95
2 Parameters
2.2 List of parameters
Notice: Information on Gn_STW/Gn_ZSW should be taken from the corresponding product documentation.
Note: The signal source for the encoder control word is set with p0480.
Description: Sets the input terminal to connect probe 1.
Value: 0: No meas probe
21: DI 1 (X07.2)
23: DI 3 (X08.2)
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency: Refer to: p0489, p0490
Note: DI: Digital Input
Description: Sets the input terminal to connect probe 2.
Value: 0: No meas probe
21: DI 1 (X07.2)
23: DI 3 (X08.2)
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency: Refer to: p0488, p0490
Note: DI: Digital Input
Description: Setting to invert the digital input signals to connect a measuring probe or an equivalent zero mark.
Bit field: Bit Signal name 1 signal 0 signal FP
00 Request function 1 Yes No -
01 Request function 2 Yes No -
02 Request function 3 Yes No -
03 Request function 4 Yes No -
04 Request command bit 0 Yes No -
05 Request command bit 1 Yes No -
06 Request command bit 2 Yes No -
07 Flying measurement mode/search for
reference mark
Flying measurement Reference marks -
13 Request absolute value cyclic Yes No -
14 Request parking encoder Yes No -
15 Request acknowledge encoder fault Yes No -
p0488[0...2] Measuring probe 1 input terminal / Meas probe 1 inp
Access level: 3 Calculated: - Data type: Integer16
Can be changed: U, T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 23 0
p0489[0...2] Measuring probe 2 input terminal / Meas probe 2 inp
Access level: 3 Calculated: - Data type: Integer16
Can be changed: U, T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 23 0
p0490 Invert measuring probe or equivalent zero mark / Pr or ZM_equiv inv
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: U, T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 4740
Min Max Factory setting
- - 0000 bin