Siemens SINAMICS G120D CU240D-2 DP - p2659 BI: EPOS referencing active feedback signal; Ref act fdbk; p2660 CI: EPOS measured value referencing; Meas val ref; p2661 BI: EPOS measured value valid feedback signal; MeasVal valid fdbk; p2662 BI: EPOS adjustment value valid feedback signal; Adj val valid FS

Siemens SINAMICS G120D CU240D-2 DP
980 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G120D
374 List Manual (LH14), 01/2016, A5E33842313
BI: p2658 = 1 signal
The position actual value received via CI: p2657 is valid.
BI: p2658 = 0 signal
The position actual value received via CI: p2657 is invalid.
Dependency: Refer to: r2526, p2657
Note: While a 0 signal is present, the position setpoint (p2665) is held at the value of 0.
Description: Sets the signal source for the feedback signal "referencing active".
BI: p2659 = 1 signal
Referencing is active.
BI: p2659 = 0 signal
Referencing is not active.
Dependency: Refer to: r2526
Description: Sets the signal source for the measured value for the function "referencing".
Dependency: Refer to: r2523
Description: Sets the signal source for the feedback signal "measured value valid".
BI: p2661 = 1 signal
The measured value received via CI: p2660 is valid.
BI: p2661 = 0 signal
The measured value received via CI: p2660 is invalid.
Dependency: Refer to: r2526, p2660
Description: Sets the signal source for the feedback signal "adjustment value valid".
BI: p2662 = 1 signal
The adjustment value received via CI: p2660 is valid.
BI: p2662 = 0 signal
The adjustment value received via CI: p2660 is not valid.
p2659 BI: EPOS referencing active feedback signal / Ref act fdbk
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3612
Min Max Factory setting
- - 2526.1
p2660 CI: EPOS measured value referencing / Meas val ref
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 3 Calculated: - Data type: U32 / Integer32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3612, 3614
Min Max Factory setting
- - 2523[0]
p2661 BI: EPOS measured value valid feedback signal / MeasVal valid fdbk
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3612, 3614, 3615
Min Max Factory setting
- - 2526.2
p2662 BI: EPOS adjustment value valid feedback signal / Adj val valid FS
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - 2526.9