Siemens SINAMICS G120D CU240D-2 DP - p0757[0...1] CU analog inputs characteristic value x1; CU AI char x1; p0758[0...1] CU analog inputs characteristic value y1; CU AI char y1; p0759[0...1] CU analog inputs characteristic value x2; CU AI char x2; p0760[0...1] CU analog inputs characteristic value y2; CU AI char y2

Siemens SINAMICS G120D CU240D-2 DP
980 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
125
2 Parameters
2.2 List of parameters
Warning: The maximum voltage difference between analog input terminals AI+, AI-, and the ground must not exceed 35 V.
Description: Sets the scaling characteristic for the analog inputs.
The scaling characteristic for the analog inputs is defined using 2 points.
This parameter specifies the x coordinate (V) of the 1st value pair of the characteristic.
Index: [0] = AI0 (X10.3)
[1] = AI1 (X10.4)
Note: The parameters for the characteristic do not have a limiting effect.
Description: Sets the scaling characteristic for the analog inputs.
The scaling characteristic for the analog inputs is defined using 2 points.
This parameter specifies the y coordinate (percentage) of the 1st value pair of the characteristic.
Index: [0] = AI0 (X10.3)
[1] = AI1 (X10.4)
Note: The parameters for the characteristic do not have a limiting effect.
Description: Sets the scaling characteristic for the analog inputs.
The scaling characteristic for the analog inputs is defined using 2 points.
This parameter specifies the x coordinate (V) of the 2nd value pair of the characteristic.
Index: [0] = AI0 (X10.3)
[1] = AI1 (X10.4)
Note: The parameters for the characteristic do not have a limiting effect.
Description: Sets the scaling characteristic for the analog inputs.
The scaling characteristic for the analog inputs is defined using 2 points.
This parameter specifies the y coordinate (percentage) of the 2nd value pair of the characteristic.
Index: [0] = AI0 (X10.3)
[1] = AI1 (X10.4)
Note: The parameters for the characteristic do not have a limiting effect.
p0757[0...1] CU analog inputs characteristic value x1 / CU AI char x1
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 9566, 9568, 9576
Min Max Factory setting
-50.000 160.000 0.000
p0758[0...1] CU analog inputs characteristic value y1 / CU AI char y1
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 9566, 9568, 9576
Min Max Factory setting
-1000.00 [%] 1000.00 [%] 0.00 [%]
p0759[0...1] CU analog inputs characteristic value x2 / CU AI char x2
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 9566, 9568, 9576
Min Max Factory setting
-50.000 160.000 10.000
p0760[0...1] CU analog inputs characteristic value y2 / CU AI char y2
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 9566, 9568, 9576
Min Max Factory setting
-1000.00 [%] 1000.00 [%] 100.00 [%]