3 Function diagrams
3.11 Setpoint channel
Fig. 3-78 3010 – Fixed speed setpoints, binary selection (p1016 = 2)
- 3010 -
Function diagram
87654321
fp_3010_97_51.vsd
Setpoint channel
SINAMICS G120D
09.12.2015 V4.7.6
Fixed speed setpoints, binary selection (p1016 = 2)
0 0 1 1
0 1 0 1
0 1 1 0
0 1 1 1
1 0 0 1
1 0 1 0
1 0 1 1
1 1 0 0
1 1 0 1
1 1 1 0
1 1 1 1
0 0 0 1
0 0 1 0
0.000
0 0 0 0
0 1 0 0
1 0 0 0
r1024
n_set_fixed eff [rpm]
n_set_fixed No act
r1197
n_set_fix select
1... 2
p1016 (1)
[3011]
1
1
1
1
2
2
2
2
[3011]
[3011]
[3011]
[2505.6]
p1020
[2505.6]
p1021
[2505.6]
p1022
[2505.6]
p1023
1 = Fixed setpoint, bit 0
1 = Fixed setpoint, bit 1
1 = Fixed setpoint, bit 2
1 = Fixed setpoint, bit 3
r1198.3
r1198
r1198.1
r1198
r1198.2
r1198
r1198.0
r1198
n_set_fixed 1 [rpm]
p1001 [D] (0.000)
n_set_fixed 2 [rpm]
p1002 [D] (0.000)
n_set_fixed 3 [rpm]
p1003 [D] (0.000)
n_set_fixed 4 [rpm]
p1004 [D] (0.000)
n_set_fixed 5 [rpm]
p1005 [D] (0.000)
n_set_fixed 6 [rpm]
p1006 [D] (0.000)
n_set_fixed 7 [rpm]
p1007 [D] (0.000)
n_set_fixed 8 [rpm]
p1008 [D] (0.000)
n_set_fixed 9 [rpm]
p1009 [D] (0.000)
n_set_fixed 10 [rpm]
p1010 [D] (0.000)
n_set_fixed 11 [rpm]
p1011 [D] (0.000)
n_set_fixed 12 [rpm]
p1012 [D] (0.000)
n_set_fixed 13 [rpm]
p1013 [D] (0.000)
n_set_fixed 14 [rpm]
p1014 [D] (0.000)
n_set_fixed 15 [rpm]
p1015 [D] (0.000)