SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
377
2 Parameters
2.2 List of parameters
Description: Displays the velocity setpoint presently being processed.
Description: Displays the acceleration override presently being processed.
Note: An override of 100% is effective in the "jogging" and "search for reference" operating modes.
Description: Displays the deceleration override presently being processed.
Note: An override of 100% is effective in the "jogging" and "search for reference" operating modes.
Description: Displays the task that is presently being processed.
Value: 0: Inactive
1: POSITIONING
2: FIXED STOP
3: ENDLESS_POS
4: ENDLESS_NEG
5: WAITING
6: GOTO
7: SET_O
8: RESET_O
9: JERK
Dependency: Refer to: p2621
r2672 CO: EPOS actual velocity setpoint / v_set act
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: Integer32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3610, 3612, 3616,
3620
Min Max Factory setting
- [1000 LU/min] - [1000 LU/min] - [1000 LU/min]
r2673 CO: EPOS actual acceleration override / a_over act
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3610, 3612, 3616,
3620
Min Max Factory setting
- [%] - [%] - [%]
r2674 CO: EPOS actual deceleration override / -a_over act
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3610, 3612, 3616,
3620
Min Max Factory setting
- [%] - [%] - [%]
r2675 CO: EPOS actual task / Task act
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: Integer16
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
0 9 -