2 Parameters
2.2 List of parameters
Description: Sets the signal source for the reference cam.
Dependency: Refer to: p2607
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source for the reversing cam in the negative direction of travel.
1 signal: Reversing cam not reached.
0 signal: Reversing cam reached.
Dependency: Refer to: p2614
Note: If, during the search for reference from the reversing cam minus and plus, a 0 signal is detected, then the axis
remains stationary (at standstill).
Description: Sets the signal source for the reversing cam in the negative direction of travel.
1 signal: Reversing cam not reached.
0 signal: Reversing cam reached.
Dependency: Refer to: p2613
Note: If, during the search for reference from the reversing cam minus and plus, a 0 signal is detected, then the axis
remains stationary (at standstill).
Description: Sets the maximum number of traversing blocks that are available.
Dependency: Refer to: p2616, p2617, p2618, p2619, p2620, p2621, p2622, p2623, p2624
p2612 BI: EPOS search for reference reference cam / Ref_cam
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3612
Min Max Factory setting
- - 0
p2613 BI: EPOS search for reference reversing cam minus / Rev minus
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3612
Min Max Factory setting
- - 1
p2614 BI: EPOS search for reference reversing cam plus / Rev plus
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3612
Min Max Factory setting
- - 1
p2615 EPOS maximum number of traversing blocks / Trav_block qty max
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: Unsigned8
Can be changed: C(17) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
1 16 16