EasyManua.ls Logo

Siemens SINAMICS G120D CU240D-2 DP - p1442[0...n] Speed controller speed actual value smoothing time; n_ctr n_act T_smth; r1444 Speed controller speed setpoint steady-state (static); n_ctrl n_set stat; r1445 CO: Actual speed smoothed; n_act smooth; p1452[0...n] Speed controller speed actual value smoothing time (sensorless); n_C n_act T_s SL

Siemens SINAMICS G120D CU240D-2 DP
980 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
209
2 Parameters
2.2 List of parameters
Description: Sets the smoothing time for the actual speed value of the speed controller for closed-loop control with encoder.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note: The smoothing must be increased if there is gear backlash. For longer smoothing times, the integral time of the
speed controller must also be increased (e.g. using p0340 = 4).
Description: Displays the sum of all speed setpoints that are present.
The following sources are available for the displayed setpoint:
- setpoint at the ramp-function generator input (r1119).
- speed setpoint 1 (p1155).
- speed setpoint 2 (p1160).
- speed setpoint for the speed pre-control (p1430).
- setpoint from DSC (for DSC active).
- setpoint via PC (for master control active).
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: r1119, p1155, p1160
Description: Display and connector output for the actual smoothed speed actual value of the speed control.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description: Sets the smoothing time for the actual speed of the speed controller for encoderless closed-loop speed control.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note: The smoothing must be increased if there is gear backlash. For longer smoothing times, the integral time of the
speed controller must also be increased (e.g. using p0340 = 4).
p1442[0...n] Speed controller speed actual value smoothing time / n_ctr n_act T_smth
Access level: 2 Calculated: p0340 = 1 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: 6020, 6040
Min Max Factory setting
0.00 [ms] 32000.00 [ms] 4.00 [ms]
r1444 Speed controller speed setpoint steady-state (static) / n_ctrl n_set stat
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Dyn. index: -
Unit group: 3_1 Unit selection: p0505 Func. diagram: 5030
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
r1445 CO: Actual speed smoothed / n_act smooth
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Dyn. index: -
Unit group: 3_1 Unit selection: p0505 Func. diagram: 6040
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
p1452[0...n] Speed controller speed actual value smoothing time (sensorless) / n_C n_act T_s SL
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: 6020, 6040
Min Max Factory setting
0.00 [ms] 32000.00 [ms] 10.00 [ms]

Table of Contents

Related product manuals